Description
Newmar GI-60-FS Galvanic Isolator (60A, Fail Safe) installs between the AC safety ground and DC bonding system, blocking most low-voltage currents and corrosive action on vital metallic components in saltwater. It is designed for boaters who want to significantly reduce galvanic corrosion on sacrificial anodes while maintaining the integrity of the critical safety ground path.
With the low voltage current blocked, this isolator delivers meaningful savings in boat haul-out fees and zinc replacement costs, and a large capacitor provides a secondary low-impedance path for AC current to reach ground. Meeting the latest ABYC A-28 2019 requirements including fail-safe operation, this isolator is certified to UL1500 for ignition protection and tested to 50°C ambient temperature. Browse more options in our battery chargers category.
Key Features: 60A, ABYC A-28 2019 compliant, fail-safe, UL1500 ignition protected, 5000A max short circuit, tested to 50°C.
Frequently Asked Questions
What does this isolator protect against? Galvanic corrosion on sacrificial anodes caused by low-voltage currents from shore power.
What does 'fail safe' mean here? The 60A fail-safe feature ensures ground connection maintenance even if the isolator fails.
What standards does this isolator meet? ABYC A-28 2019 and UL1500 for ignition protection.
Specifications
- MPN:
- GI-60-FS
- Amperage:
- 60A
- Shore Power Voltage:
- 115-230V
- Max Short Circuit:
- 5000 Amps
- Stray Current Protection:
- Up to 1.4 VDC
- Standard:
- ABYC A-28 2019, UL1500 Ignition Protected
- Weight:
- 5.3 lbs
Description
Newmar GI-60-FS Galvanic Isolator (60A, Fail Safe) installs between the AC safety ground and DC bonding system, blocking most low-voltage currents and corrosive action on vital metallic components in saltwater. It is designed for boaters who want to significantly reduce galvanic corrosion on sacrificial anodes while maintaining the integrity of the critical safety ground path.
With the low voltage current blocked, this isolator delivers meaningful savings in boat haul-out fees and zinc replacement costs, and a large capacitor provides a secondary low-impedance path for AC current to reach ground. Meeting the latest ABYC A-28 2019 requirements including fail-safe operation, this isolator is certified to UL1500 for ignition protection and tested to 50°C ambient temperature. Browse more options in our battery chargers category.
Key Features: 60A, ABYC A-28 2019 compliant, fail-safe, UL1500 ignition protected, 5000A max short circuit, tested to 50°C.
Frequently Asked Questions
What does this isolator protect against? Galvanic corrosion on sacrificial anodes caused by low-voltage currents from shore power.
What does 'fail safe' mean here? The 60A fail-safe feature ensures ground connection maintenance even if the isolator fails.
What standards does this isolator meet? ABYC A-28 2019 and UL1500 for ignition protection.
Specifications
- MPN:
- GI-60-FS
- Amperage:
- 60A
- Shore Power Voltage:
- 115-230V
- Max Short Circuit:
- 5000 Amps
- Stray Current Protection:
- Up to 1.4 VDC
- Standard:
- ABYC A-28 2019, UL1500 Ignition Protected
- Weight:
- 5.3 lbs
Specifications
MPN, Amperage, Shore Power Voltage, Max Short Circuit, Stray Current Protection, Standard, Weight,
Specifications
- MPN:
- GI-60-FS
- Amperage:
- 60A
- Shore Power Voltage:
- 115-230V
- Max Short Circuit:
- 5000 Amps
- Stray Current Protection:
- Up to 1.4 VDC
- Standard:
- ABYC A-28 2019, UL1500 Ignition Protected