Description

The Blue Sea Systems 7289 is an 80A C-Series triple pole toggle breaker in white, with 5,000 ampere interrupt capacity.

Pole count decides the job here. A double pole breaker used as a 120 volt AC main switches hot and neutral. A triple pole like this is used as a 240 volt AC main, switching both lines and the neutral together. Ordering the wrong pole count leaves a conductor live behind an open main, which is not what anyone working downstream would assume.

On a multi-pole breaker a trip in any one pole opens all of them, so a fault on one leg does not leave the others live. A half-dead system is harder to diagnose than a dead one, and more dangerous to work on.

Five thousand amperes of interrupt capacity is what ABYC calls for in 120/240 volt 50 ampere main protection. The trip free design cannot be held on during a fault current condition, so a fault stays disconnected rather than being overridden by hand. Explore more marine circuit breakers.

  • Three poles for a 240V main, two for a 120V one
  • The wrong count leaves a conductor live
  • A trip in one pole opens all three
  • 5,000A interrupt, what ABYC calls for

Specifications

Actuator Style:
Toggle
Amperage:
80A
Color:
White
Product Type:
Circuit Breaker
Google Feed:
Yes
Bing Feed:
Yes
Pinterest Feed:
Yes
Feed Brand:
Blue Sea
Feed MPN:
7289
Feed GTIN:
632085072896

Description

The Blue Sea Systems 7289 is an 80A C-Series triple pole toggle breaker in white, with 5,000 ampere interrupt capacity.

Pole count decides the job here. A double pole breaker used as a 120 volt AC main switches hot and neutral. A triple pole like this is used as a 240 volt AC main, switching both lines and the neutral together. Ordering the wrong pole count leaves a conductor live behind an open main, which is not what anyone working downstream would assume.

On a multi-pole breaker a trip in any one pole opens all of them, so a fault on one leg does not leave the others live. A half-dead system is harder to diagnose than a dead one, and more dangerous to work on.

Five thousand amperes of interrupt capacity is what ABYC calls for in 120/240 volt 50 ampere main protection. The trip free design cannot be held on during a fault current condition, so a fault stays disconnected rather than being overridden by hand. Explore more marine circuit breakers.

  • Three poles for a 240V main, two for a 120V one
  • The wrong count leaves a conductor live
  • A trip in one pole opens all three
  • 5,000A interrupt, what ABYC calls for

Specifications

Actuator Style:
Toggle
Amperage:
80A
Color:
White
Product Type:
Circuit Breaker
Google Feed:
Yes
Bing Feed:
Yes
Pinterest Feed:
Yes
Feed Brand:
Blue Sea
Feed MPN:
7289
Feed GTIN:
632085072896

Specifications

Actuator Style, Amperage, Color, Product Type, Google Feed, Bing Feed, Pinterest Feed, Feed Brand, Feed MPN, Feed GTIN,

Specifications

Actuator Style:
Toggle
Amperage:
80A
Color:
White
Product Type:
Circuit Breaker
Google Feed:
Yes
Bing Feed:
Yes
Pinterest Feed:
Yes
Feed Brand:
Blue Sea
Feed MPN:
7289
Feed GTIN:
632085072896

Our customers love it

Review this Product
Reviews (0) Write a Review

Be the first to write a review.